Gear pump, 200FZ0015DS, Hydrocar FZ0 15, right-hand drive, ISO
- Hydrocar external gear pump, type FZ0 15, with a flow rate of 15 l/min (at 1,000 rpm), clockwise¹, with shaft according to ISO 14:1982 (DIN 5462). New version of the 200NFA pump.
NOT SURE WHAT THE DIRECTION OF ROTATION OF YOUR PUMP IS? CHECK HERE
Hydrocar external gear pump, type FZ0 15, with a flow rate of 15 l/min (at 1000 rpm), with right-hand direction of rotation¹, from shaft according to ISO 14:1982 (DIN 5462). New version of the 200NFA pump .
BASIC DATA
Geometric working volume | 15.0 cm3/rev. |
Flow capacity (at 1000 rpm) | 15.0 l/min |
Maximum operating pressure (continuous) | 315 bar |
Direction of rotation¹ | clockwise |
Maximum speed (continuous) | 2500 rpm |
Minimum speed |
450 rpm |
Shaft drive |
B8×32×36 ISO 14:1982 (DIN 5462) |
Mounting flange | according to ISO 7653:1985 |
Typical application | trucks |
Country of origin | Italy |
Manufacturer's website | www.hydrocar.com |
SUPPLEMENTARY INFORMATION
Torque (at maximum pressure) | 76.21 Nm |
Own weight | 10.8 kg |
Temperafront loader oil operation (permissible range) |
-10÷80° C |
Recommended oil viscosity² | 12÷100 cSt |
Axial length after installation | 169 mm |
Cross section | 150×120 mm |
Suction connection | g ¾" female thread (according to BSPP³) |
Discharge connection | g ½" female thread (according to BSPP³) |
Similar to:
200HPS013DS 200HPS013SS 200HPS016DS 200HPS016SS 200HPS022DS 200HPS022SS 200HPS022SS 200HPS025DS 200HPS025SS 3.1.58.016.0.4.0.0 3.1.58.018.0.4.0.0 3.1.58.022.0.4.0.0 3.1.7.1.015.X.0.X.0 3.1.7.1.022.X.0.X.0 22149016 22247017 22248017 22677017 22678017 BLGP15BI4HRP BLGP25BI4HRP 10500330124 10500330133 10500330142 10500330151 10500330160 10500330179 10500330204 10500330213 10500330259 10500330268 10500330142 10500330151 10500330160 10500330179 10500330204 10500330213 10500330259 10500340140 10500340159 10500340168 10500340177 10500340177 10500340202 10500340211 10500340257 10500340266 10501110173 10501110182 10501110226 10501110235 ZL20.4
- The direction of rotation is determined by looking at the pump from shaft. Clockwise direction - clockwise, counterclockwise direction- counterclockwise.Running the pump with the wrong direction of rotation can cause damage to the pump.
- The pump is not suitable for use with oil-in-water emulsions (HFA, HFB, HFC) and synthetic non-oil hydraulic fluids (HFD) - according to the 5th Report of the European Commission for Mining Safety.
- British Standard Pipe Parallel - British StandardPipe Parallel , inchcylindrical thread , one of the Whitworthpipe threads(BSP) denoted by the letter G.
Note: The technical and operational parameters of the product given above are for informational purposes. The owner and administrator of the online store hydromech.eu are not responsible for their compliance with the parameters of the product supplied by the manufacturer. The source data are provided in the manufacturer's brochure, which can be downloaded from the "Download" tab (below).