Multi-piston pump, 201PEC98WSE, Hydrocar PE 100, bi-directional, ISO
- Hydrocar multi-piston pump, type PE 100, with a flow rate of 97.3 l/min (at 1000 rpm), with uNIversal direction of rotation¹, with shaft according to ISO 14:1982 (DIN 5462).
Hydrocarmulti-pistonpump , type PE 100 with a flow rate of 97.3 l/min (at 1000 rpm), with uNIversal direction of rotation¹, with shaft according to ISO 14:1982 (DIN 5462).
BASIC DATA
Geometric working volume | 97.3 cm3/rev. |
Flow capacity (at 1000 rpm) | 97.3 l/min |
Maximum working pressure (continuous) | 290 bar |
Direction of rotation¹ | uNIversal |
Maximum speed (continuous) | 1500 rpm |
Minimum speed | 300 rpm |
Shaft drive |
B8×32×36 ISO 14:1982 (DIN 5462) |
Mounting flange | according to ISO 7653:1985 |
Typical application | trucks |
Country of origin | Italy |
Manufacturer's website | www.hydrocar.com |
SUPPLEMENTARY INFORMATION
Torque (at maximum pressure) | |
Own weight | 20.8 kg |
Temperafront loader oil operation (permissible range) |
-10÷80° C |
Recommended oil viscosity² | 12÷100 cSt |
Axial length after installation | 263.0 mm |
Cross section | |
Suction connection | g 2" female thread (acc. to BSPP³) |
Discharge connection | g 1" female thread (according to BSPP³) |
- The direction of rotation is determined by looking at the pump from shaft. Clockwise direction - clockwise, counterclockwise direction - counterclockwise. Running the pump with the wrong direction of rotation can cause damage to the pump.
- The pump is not suitable for use with oil-in-water emulsions (HFA, HFB, HFC) and synthetic non-oil hydraulic fluids (HFD) - according to the 5th Report of the European Commission for Mining Safety.
- British Standard Pipe Parallel - British StandardPipe Parallel , inchcylindrical thread , one of the Whitworthpipe threads(BSP) denoted by the letter G.
Note: The technical and operational parameters of the product given above are for informational purposes. The owner and administrator of the online store hydromech.eu are not responsible for their compliance with the parameters of the product supplied by the manufacturer. The source data are provided in the manufacturer's brochure, which can be downloaded from the "Download" tab (below).