Multi-piston pump, 201PE250ZSE, Hydrocar PE 250, bi-directional 50+50 , ISO
- Hydrocar twin piston pump, type PE 250, with a flow rate of 50+50 l/min (at 1000 rpm), with uNIwersal direction of rotation¹, with shaft according to ISO 14:1982 (DIN 5462).
Hydrocartwin pistonpump , type PE 250 with a flow rate of 50+50 l/min (at 1000 rpm), with uNIwersal direction of rotation¹, with shaft according to ISO 14:1982 (DIN 5462).
BASIC DATA
Geometric working volume | 50+50 cm3/rev. |
Flow capacity (at 1000 rpm) | 50+50 l/min |
Maximum working pressure (continuous) | 300 bar |
Direction of rotation¹ | uNIversal |
Maximum rotation speed (continuous) | 1600 rpm |
Minimum speed |
400 rpm |
Shaft drive |
B8×32×36 ISO 14:1982 (DIN 5462) |
Mounting flange | according to ISO 7653:1985 |
Typical application | trucks |
Country of origin | Italy |
Manufacturer's website | www.hydrocar.com |
SUPPLEMENTARY INFORMATION
Torque (at maximum pressure) | |
Own weight | 17.7 kg |
Temperafront loader oil operation (permissible range) |
-10÷80° C |
Recommended oil viscosity² | 12÷100 cSt |
Axial length after installation | 276 mm |
Cross section | |
Suction connection | g 1 1/2" female thread (acc. to BSPP³) |
Discharge connection | g 1" female thread (according to BSPP³) |
- The direction of rotation is determined by looking at the pump from shaft. Clockwise direction - clockwise, counterclockwise direction - counterclockwise. Running the pump with the wrong direction of rotation can cause damage to the pump.
- The pump is not suitable for use with oil-in-water emulsions (HFA, HFB, HFC) and synthetic non-oil hydraulic fluids (HFD) - according to the 5th Report of the European Commission for Mining Safety.
- British Standard Pipe Parallel - British StandardPipe Parallel , inchcylindrical thread , one of the Whitworthpipe threads(BSP) denoted by the letter G.
Note: The technical and operational parameters of the product given above are for informational purposes only. The owner and administrator of the online store hydromech.eu are not responsible for their compliance with the parameters of the product supplied by the manufacturer. The source data are provided in the manufacturer's brochure, which can be downloaded from the "Download" tab (below).